24/7 Chat Available
24/7 Chat Available
Pre-owned
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Add the whole set in one go.
Oxford Joerns Pro Journey 155 Folding Patient Hoist
£599.99
This item
Joerns Oxford Disposable Standing Sling
£11.99
The Oxford Journey is an active stand aid: it raises a patient who can bear some weight and take part in the movement from sitting to standing, and holds them there for a transfer or for personal care. It is not a passive hoist and does not lift a fully dependent patient in a full body sling.
It folds flat for storage and transport, splits into a base assembly and a mast and boom assembly for carrying, and runs on a removable power pack. This unit is pre-owned. A standing sling is not included, and the inspection requirements below apply before it is used with a patient.
Before this equipment lifts anybody
What is included| Item | Detail | Condition |
|---|---|---|
| Oxford Journey stand aid | Mast, base and boom assembly with cow horn, knee pad and foot tray | USED |
| Power pack | Removable battery pack fitted to the mast | USED |
| Item | Detail | Status |
|---|---|---|
| Standing sling | Sized to the patient and matched to this lift. The device cannot be used without one | ADD-ON |
| Battery charger | Charger unit for the power pack | ADD-ON |
| Spare power pack | Second battery, so the lift stays available while one charges | SOLD SEPARATELY |
| Report of thorough examination | Six monthly LOLER examination by a competent person | NOT INCLUDED |
| Service, load test or commissioning | Engineer service and handover on site | NOT INCLUDED |
Checked before dispatch
These are in-house workshop checks. Damaged or non-working items are not dispatched. No engineer service, load test or LOLER thorough examination is included, and this item may require service. Thorough examination, planned maintenance, electrical safety testing and ongoing maintenance under PUWER 1998 remain with the organisation operating the equipment.
A passive hoist takes the whole weight of a patient in a full body sling and moves them, and it asks nothing of the patient beyond tolerating the sling. An active stand aid does something different: it gives a patient who retains some standing ability the leverage to get up. The patient's feet stay on the tray, their knees rest against the pad, they hold the cow horn handles, and the boom lifts through the sling under their arms and around their back so the movement is assisted rather than replaced. That distinction is the whole basis of selecting between the two, and it is why a stand aid is the wrong device for a fully dependent patient and a passive hoist is an unnecessary loss of independence for someone who can still stand with help.
What makes the Journey unusual within its class is that it folds. Most stand aids are a fixed frame that lives in a corner of the room. This one collapses to 525 mm high, separates into a base at 18.2 kg and a mast and boom at 19.2 kg, and goes in a car boot, which is why it turns up in community teams, in single-handed care and in homes where a permanent frame is not welcome. The adjustable cow horn extends the range of patient heights one unit can serve, which matters where a facility would otherwise hold two sizes.
Two practical points. The total weight of 40.2 kg is manageable when split, but the base assembly alone is still a two person lift into a vehicle for many people, and the folded depth of 1040 mm needs checking against the boot before anyone assumes it travels. And the Smart Monitor records service and diagnostic data, which is useful on a pre-owned unit: an engineer can read the history at first service rather than starting blind.
| Manufacturer | Oxford, Joerns Healthcare |
| Model | Journey |
| Device type | Active stand aid, folding, battery powered |
| Condition | Pre-owned |
| Safe working load | 155 kg |
| Overall length | 935 mm to 1000 mm |
| Overall height | 1130 mm to 1600 mm |
| Height folded | 525 mm |
| Depth folded | 1040 mm |
| Widest point, between support handles | 680 mm |
| Height to attachment point | 720 mm to 1530 mm |
| Turning radius | 1145 mm |
| Legs open, external and internal width | 970 mm and 875 mm |
| Legs closed, external and internal width | 685 mm and 590 mm |
| Overall height of legs | 110 mm |
| Ground clearance | 30 mm |
| Front castors | 75 mm twin |
| Rear castors | 100 mm braked |
| Total weight with power pack | 40.2 kg |
| Mast, base and boom assembly | 37.4 kg |
| Power pack | 2.8 kg |
| Base assembly | 18.2 kg |
| Mast and boom assembly, without battery | 19.2 kg |
Specification limited to what is confirmed
Delivery, lifting and access
| Task | Interval |
|---|---|
| Visual check of sling, attachment points, hand control lead and castors | Before every use |
| Confirm the emergency stop and manual emergency lowering operate | Before every use |
| Clean the frame, knee pad, handles and foot tray with an approved disinfectant | Between patients |
| Charge the power pack and check it holds charge | Daily in use, or after each session |
| LOLER thorough examination by a competent person, covering the lift and every sling | At least every six months |
| Planned maintenance and electrical safety testing | Annually, or to the manufacturer's schedule |
Intervals follow the manufacturer instructions and the statutory examination requirements for equipment used to lift people.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article