The Promeba PS-250 Evacuation Chair is a purpose-built stairway evacuation device designed to assist the safe, controlled descent of a seated occupant during an emergency evacuation. Understanding how to deploy, maintain and store it correctly is essential for any organisation that relies on it as part of a formal evacuation plan.
The Promeba PS-250 Evacuation Chair is designed for stairway descent only. It is not a general-purpose wheelchair, a transit chair or a hoist substitute. Its tracked braking system allows a single trained operator to guide an occupant down stairs in a controlled manner without lifting.
Operation requires specific training. An untrained operator cannot reliably control descent speed or manage an occupant safely on a stairway. Training is the responsibility of the operating organisation, not the supplier. Competence records should be maintained in line with the organisation's emergency evacuation procedure.
Organisations using evacuation chairs in a workplace setting should be aware of relevant legislation, including the Regulatory Reform (Fire Safety) Order 2005 and the requirements of the Equality Act 2010 in relation to provision for persons with reduced mobility. This article provides general guidance only. Consult a qualified fire safety consultant or responsible person for site-specific obligations.
![]() |
Promeba PS-250 Evacuation Chair £449.99 Buy nowView product |
Before each deployment or practice drill, carry out a visual and functional check. The following points should be verified:
The PS-250 should be stored at the designated refuge point or as directed by the site's personal emergency evacuation plan (PEEP). It must remain accessible at all times. Do not store it behind locked doors or stacked items. The storage location should be clearly signed.
Maintain a log of each inspection, drill and use. This supports compliance with PUWER 1998 (Provision and Use of Work Equipment Regulations), which requires that work equipment is maintained in a safe condition and that maintenance records are kept. The competent person responsible for the chair should be named in those records.
The occupant should be seated fully back in the chair with the safety belt secured snugly across the lap or chest as the design specifies. Confirm the occupant is stable before beginning descent. Do not begin stairway descent until the belt is fastened and the operator is in full control of the handles.
The operator faces away from the stairway, maintaining a firm two-handed grip on the handles throughout the descent. The braking mechanism regulates speed automatically on most tracked designs, but the operator must remain alert and in contact at all times. The PS-250 is not suitable for spiral staircases or stairs below the minimum tread depth specified by the manufacturer. Check the manufacturer instructions for exact stairway compatibility before designating a route.
After any use, including drills, inspect the chair before returning it to its storage position. If any component shows wear, damage or functional concern, remove the chair from service and arrange assessment or replacement before the next required use. Do not return a chair to service with a known defect.
Routine care keeps the PS-250 ready for immediate deployment. The following intervals are a general guide. Always follow the manufacturer instructions, which take precedence over this table.
If the chair has been used to evacuate a patient or resident in a clinical, ward or care setting, decontaminate all contact surfaces in line with the organisation's infection control protocol before returning the chair to service. Upholstery condition and cleanability should be factored into ongoing inspection. Consumable items such as the safety belt should be assessed at each inspection and replaced when wear is evident.
Withdraw the PS-250 from service immediately if any of the following are present: visible damage to the track belts, failure of the braking mechanism during a test, buckle failure or fraying belt, frame deformation or a locking joint that does not hold. Do not attempt field repair of safety-critical components. Refer to the manufacturer or a competent service agent.
The Promeba PS-250 Evacuation Chair performs a specific, safety-critical function. Getting the most from it means keeping it correctly stored, regularly inspected and operated only by trained personnel. Maintenance records support both PUWER compliance and organisational accountability. Manufacturer instructions take precedence over general guidance in all cases. If your organisation has a formal PEEP in place, ensure the PS-250 is integrated into that plan with named operators, a designated storage point and a clear inspection schedule.
![]() |
Ready to move forward with the Promeba PS-250 Evacuation Chair? Shop the Promeba PS-250 Evacuation Chair |
SelfiMed UK
BLACK FRIDAY
+ up to −80% on selected items, no code needed
Join our list for deal alerts, restocks and CPAP tips. Your code appears straight away.
Free UK mainland delivery over £300 · next-day dispatch before 1pm
By signing up you agree to receive marketing emails from SelfiMed UK. Unsubscribe at any time. Code valid on all products until Monday 30 November 23:59. One discount per item: items already at −50% or −80% keep that deal instead.
It's already in your basket, so 10% comes off at checkout.
Valid on all products. One discount per item. Ends Monday 30 November 23:59.
Jätä kommentti