24/7 Chat Available
24/7 Chat Available
Pre-owned
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Add the whole set in one go.
Labcold Benchtop Intellicold Pharmacy Fridge - Refurbished
£449.99
This item
This Labcold IntelliCold benchtop pharmacy fridge holds vaccines and temperature sensitive medicines inside a controlled 2 to 8 degrees C range, with a factory set point of 5 degrees C. It suits GP surgeries, community pharmacies, clinics and vaccination centres that have to hold cold chain stock and produce a temperature record for it.
The IntelliCold touch screen controller monitors two probes, one of them a 1 m wandering probe that can be placed anywhere in the cabinet, and logs temperatures automatically around the clock for transfer to a computer. The unit is supplied pre-owned and has been checked in the Elarix workshop before dispatch.

| Item | Detail | Condition |
|---|---|---|
| Labcold IntelliCold pharmacy fridge | 36 litre benchtop cabinet with solid lockable door | REFURBISHED |
| IntelliCold touch screen controller | Fitted to the cabinet, with minimum and maximum display and alarms | USED |
| Secondary wandering probe | 1 m probe, positioned anywhere inside the cabinet | USED |
| Wall mounting brackets | Supplied for wall mounted installation in place of benchtop use | USED |
| Item | Detail | Status |
|---|---|---|
| Calibration certificate | No certificate is supplied with this unit | NOT INCLUDED |
| Reference thermometer | Independent calibrated thermometer for verifying the display | SOLD SEPARATELY |
| Shelving or baskets | Internal shelf configuration is not confirmed on this unit | NOT INCLUDED |
| Door key | Supply of a key with this unit is not confirmed | NOT INCLUDED |
| Data download lead or software | Method of transferring logged data to a computer is not confirmed | NOT INCLUDED |
| Wall fixings | Anchors suited to the wall construction on site | NOT INCLUDED |

Checked before dispatch
These are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service and calibration is not included, and this item may require service and calibration. Planned maintenance, periodic electrical safety testing and ongoing maintenance under PUWER 1998 remain with the operating organisation.
Verify performance before any stock is loaded
A domestic fridge is built to keep food cold on average. It cycles well below 2 degrees C at the back of the cabinet and swings above 8 degrees C after the door is opened, and it gives no record of either. Vaccines lose potency at both ends of that swing, and a frozen vaccine is a discarded vaccine. A pharmacy fridge is built the other way round: fan assisted circulation to hold the whole interior inside a narrow band, a controller that watches the actual air the stock sits in, and a log that proves what happened overnight and at the weekend. When a batch is questioned months later, the log is the evidence.
The two probe arrangement is the part that matters most in daily use. One probe reports the cabinet, and the wandering probe is placed where the stock actually sits, in the busiest shelf or inside a glycol bottle, so the record reflects the medicine rather than the airflow. Minimum and maximum values are held and displayed, which is what a daily temperature check needs, and the alarms cover the three failures that spoil stock unnoticed: the temperature drifting, the door left ajar, and the power going off while the building is empty. Battery back-up keeps the controller and its alarms alive through a power cut, and the remote alarm contacts allow the unit to be tied into a building alarm system for out of hours cover.
Two trade-offs are worth stating. At 36 litres this is a small cabinet, sized for a treatment room or a single clinic session rather than a whole practice stock holding, and a solid door means checking stock requires opening it, which is better for light sensitive medicines but adds a warm air intrusion each time. And because the unit is pre-owned, it arrives without a calibration certificate, so the receiving organisation carries out its own verification against a calibrated reference before the readings are relied on for cold chain records. This is the wrong cabinet for frozen vaccine storage, for blood bank use, which is separately specified, and for laboratory samples that need a different range or a validated mapping report.
| Manufacturer | Labcold |
| Range | IntelliCold |
| Product type | Pharmacy refrigerator |
| Installation | Benchtop, or wall mounted using the supplied brackets |
| Condition | Pre-owned |
| Gross capacity | 36 litres |
| Temperature range | 2 to 8 degrees C |
| Set point | 5 degrees C |
| Controller | IntelliCold touch screen, locking after 30 seconds |
| Temperature probes | Two, including a 1 m secondary wandering probe |
| Data logging | Automatic, 24 hours a day, transferable to a computer |
| Alarms | High and low temperature, door open, power failure |
| Alarm back-up | Battery back-up for controller and alarms |
| Remote alarm contacts | Fitted |
| Cooling | Fan assisted |
| Defrost | Off-cycle automatic |
| Door | Solid, self-closing, lockable |
| Internal light | Fitted |
| Refrigerant | Contains no ammonia |
| External dimensions (H x W x D) | 540 x 450 x 510 mm |
| Internal dimensions (H x W x D) | 392 x 331 x 226 mm |
| Net weight | 30 kg |
Specification limited to what is confirmed
Delivery, lifting and wall mounting
| Task | Interval |
|---|---|
| Record current, minimum and maximum temperatures, then reset | Every working day |
| Check the door seal, self-closing action and that vents are clear | Weekly |
| Clean the interior and the controller surface | Weekly, and after any spill |
| Clean the condenser area and check for dust build-up | Quarterly |
| Verify the display against a calibrated reference thermometer | Annually, and after any move or repair |
| Download and archive the logged temperature data | To local cold chain policy |
Intervals follow common cold chain practice and are adjusted to the manufacturer instructions and local medicines policy.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article