Blease 2200 Anaesthesia Ventilator with Valve and Hose – Pneumatic & MRI-Compatible
The Blease 2200 Anaesthesia Ventilator is a pneumatically driven, time-cycled ventilator designed for use in MRI environments. It supports Volume Control Ventilation (VCV) and is compatible with a variety of breathing circuits, including circle systems, Bain, and Jackson-Rees paediatric circuits. Lightweight, portable, and robust, it is ideal for anaesthesia applications, veterinary use, and emergency ventilation.
Key Features & Benefits
✅ Compact & Portable – Lightweight (3.15 kg), easy to transport and set up.
✅ Pneumatically Driven – Requires no electrical power; operates via high-pressure oxygen supply.
✅ Volume Control Ventilation (VCV) – Delivers consistent, controlled tidal volume for patient safety.
✅ MRI-Compatible – Ideal for magnetic environments where electronic ventilators cannot be used.
✅ Versatile Circuit Compatibility – Supports circle, semi-closed Bain, and Jackson-Rees circuits.
✅ Wide Ventilation Range – Smoothly adjustable frequency (4–54 breaths/min) and minute volume (3–20 L/min).
✅ Audible & Visual Alarms – Airway pressure, low supply pressure, and minute volume alarms ensure patient safety.
✅ Durable & Reliable – Tested for vibration resistance and airworthiness for extreme conditions.
✅ Integrated PEEP Option – Can be fitted with a PEEP valve for enhanced respiratory support.
✅ Multiple Gas Supply Options – Runs off bottled oxygen or wall outlet supply.
Specifications
General
✔️ Brand: Blease
✔️ Model: 2200
✔️ Dimensions: 215 × 90 × 215 mm
✔️ Weight: 3.15 kg (7.3 lbs)
Performance & Ventilation
✔️ Ventilation Type: Volume Control Ventilation (VCV)
✔️ Minute Volume: 3 – 20 L/min
✔️ Ventilation Frequency: 4 – 54 breaths/min
✔️ I:E Ratio: 1:1.5
✔️ Dead Space Volume: Approx. 12 mL
✔️ Gas Consumption: Approx. 1.0 L/min for internal control
Pressure & Alarm Systems
✔️ Maximum Airway Pressure: 25 – 60 mbar/cm H₂O (adjustable)
✔️ Airway Pressure Alarm (Paw High): Triggers if actual value exceeds set Pmax
✔️ Airway Pressure Alarm (Paw Low): Triggers if inspiratory pressure is below 10 mbar/cm H₂O
✔️ Supply Pressure Low Alarm: Activates when pressure drops below 2.7 bar (40 psi)
✔️ Safety Valve Opening Pressure: 80 mbar/cm H₂O
Operating Conditions
✔️ Temperature Range: –18°C to +50°C
✔️ Humidity: 15% – 95%
✔️ Atmospheric Pressure: 700 – 1100 hPa
Power & Connectivity
✔️ Supply Pressure: 2.7 – 6 bar (40 – 88 psi at 60 L/min)
✔️ Gas Supply Options: High-pressure oxygen (bottle or wall outlet)
✔️ Switch to Air Mix: Approx. 60% O₂
✔️ Switch to No Air Mix: 100% O₂
Ideal Applications
✔️ Anaesthesia in MRI Suites – Safe for magnetic environments.
✔️ Veterinary Clinics – Ideal for small animals, reptiles (tick & snake bite ventilation), and paediatric cases.
✔️ Emergency Ventilation – Reliable pneumatic operation in field or hospital settings.
✔️ Mobile & Transport Ventilation – Lightweight, durable, and vibration-tested for movement.
What’s Included?
✔️ Blease 2200 Anaesthesia Ventilator
✔️ Reusable Ventilator Circuit
✔️ High-Pressure Oxygen Hose
✔️ User Manual (Download Below)
📥 Download Manual Here
Order the Blease 2200 Anaesthesia Ventilator Today!
A cost-effective, MRI-compatible, and pneumatically driven ventilator for safe and efficient anaesthesia delivery.