Philips DreamStation 2 Advanced Auto CPAP Machine with Humidifier
Philips DreamStation 2 Advanced Auto CPAP Machine with Integrated Humidifier, Pre-Owned
The Philips DreamStation 2 Advanced Auto is a compact auto-adjusting CPAP machine for the treatment of obstructive sleep apnoea. Pressure adjusts automatically across a 4 to 20 cm H2O range in response to detected respiratory events, with Flex pressure relief easing the transition at exhalation. The humidifier is built into the body of the device rather than clipping on, which keeps the overall footprint small on a bedside table. A full colour touchscreen replaces the dial-and-menu arrangement of the earlier generation, and Ramp Plus lets the wearer start the night at a lower, more comfortable pressure. This unit is pre-owned.
What is included
| Item | Detail | Condition |
|---|---|---|
| DreamStation 2 Advanced Auto | Philips auto-adjusting CPAP machine, main unit | USED |
| Integrated humidifier | Built-in humidifier with 325 ml water tank | USED |
What is not included
| Item | Detail | Status |
|---|---|---|
| Power supply unit and mains lead | Required to run the device | SOLD SEPARATELY |
| Mask and headgear | Any interface, selected to suit the wearer | SOLD SEPARATELY |
| Tubing | Standard 15 mm or 22 mm hose, or heated tubing | SOLD SEPARATELY |
| Filters | Reusable pollen filter and disposable ultra-fine filter | SOLD SEPARATELY |
| Carry case | Travel bag for the device | SOLD SEPARATELY |
| SD card | Therapy data card | SOLD SEPARATELY |
| Distilled water | Required for the humidifier tank | SOLD SEPARATELY |
| Setup and pressure prescription | Therapy settings determined by the responsible sleep service | SOLD SEPARATELY |
Checked before dispatch
- Cleaned and inspected.
- Powered up and function tested, including blower operation, humidifier heater and touchscreen response.
- Humidifier tank and seal checked for cracks and correct seating.
- Air outlet, filter housing and casing visually inspected for damage.
These are in-house workshop checks. Damaged or non-working items are not dispatched. A full engineer service is not included unless this listing states that the unit has been serviced.
Before first use
- Therapy pressure, auto range and comfort settings should be set by the sleep service or clinician responsible for the wearer's care, not carried over from a previous user.
- Fit fresh filters and use a fresh mask and tubing. These are personal items and are not transferred between users.
- Fill the humidifier tank with distilled water only. Tap water leaves mineral deposits that damage the tank and reduce humidifier performance.
Key features
Technical specifications
| Manufacturer | Philips Respironics |
| Model | DreamStation 2 Advanced Auto |
| Device type | Auto-adjusting CPAP machine |
| Therapy modes | CPAP and Auto CPAP |
| Pressure range | 4 to 20 cm H2O |
| Flex pressure relief | Off, 1, 2, 3 |
| Ramp Plus time | 15, 30 or 45 minutes |
| Ramp Plus start pressure | 4 to 10 cm H2O |
| Humidification | Integrated, heated tube supported |
| Humidifier capacity | 325 ml |
| Data storage | Onboard, up to 6 months |
| Connectivity | Bluetooth and cellular |
| App | Philips DreamMapper |
| Altitude compensation | Automatic |
| Filters | Reusable pollen filter, disposable ultra-fine filter |
| Controls | Colour LCD touchscreen |
| Dimensions | 256.8 x 158.5 x 84.8 mm |
| Weight without power supply | 1.04 kg |
| Power requirements | 100 to 240 V AC, 50/60 Hz |
| Condition | Pre-owned |
Routine care guidance
| Component | Action | Interval |
|---|---|---|
| Humidifier tank | Empty, rinse and dry, refill with fresh distilled water | Daily |
| Reusable pollen filter | Rinse in warm water, air dry fully before refitting | Weekly |
| Disposable ultra-fine filter | Fit a fresh filter, or sooner if visibly soiled | Monthly |
| Tubing | Wash in warm soapy water, rinse and hang to dry away from direct sunlight | Weekly |
| Mask and headgear | Clean per the interface instructions | Per interface guidance |
| Device exterior | Wipe with a damp cloth, device disconnected from the mains | Weekly |
| Humidifier tank condition | Inspect the seal and body for cracks, clouding and scale, renew when worn | Every six months |
Intervals above are general guidance for a single user. The manufacturer instructions for use take precedence.