Chatt dygnet runt
Chatt dygnet runt
The Linet Elengeza is an electrically adjustable hospital bed designed for clinical ward use. Choosing the right model requires a clear understanding of what the specification covers, what condition the unit is in, and what is and is not included in the purchase. The notes below set out the practical factors a clinician, procurement officer or biomedical engineer should check before ordering.
Inspect the welded steel frame for deformation, corrosion or cracked welds. On a pre-owned unit, photographs should form part of the description. If they are not provided, ask before ordering. A compromised frame may affect safe working load and render the bed unsuitable for service without repair.
The Elengeza uses electric motors to adjust backrest, knee break and, on some configurations, overall bed height. Confirm that all motor functions operate without error codes or audible grinding. The handset should be present and fully functional. A missing or damaged handset is a significant limitation because the bed cannot be adjusted at the bedside without it.
Verify the safe working load stated by the manufacturer against the patient population the bed will serve. Check that the full range of adjustment positions is available and that no mechanical stops have been added informally. The declared safe working load governs the safe use of the complete system, including any mattress fitted.
![]() |
Linet Elengeza Electric Hospital Bed with Controllers and Mattress £499.99 Buy nowView product |
The Elengeza is supplied without a mattress unless stated explicitly in the listing. A compatible mattress must be sourced separately. Confirm platform dimensions, deck profile and the maximum mattress depth the frame accommodates before ordering a replacement.
Side rails should be checked for secure locking, smooth release and the absence of cracks or bent components. Damaged or incorrectly specified rails can present an entrapment risk. Operating organisations are responsible for assessing entrapment risk under their own policies and applicable guidance. This responsibility remains with the operating organisation, not with the supplier.
A pre-owned electric hospital bed should arrive having passed a basic in-house function check and visual inspection. Planned maintenance, periodic electrical safety testing and any engineer service required to bring the unit to current standard remain the responsibility of the operating organisation. The listing should state clearly what checks were performed before dispatch and what was not done.
Under the Provision and Use of Work Equipment Regulations 1998 (PUWER), the organisation putting the bed into service is responsible for ensuring it is suitable, maintained in a safe condition and used only by people who have received adequate information and training. A supplier dispatch check does not substitute for this obligation.
On a pre-owned Elengeza, ask for the approximate age, ward history and any known faults. Vague condition descriptions are not sufficient for clinical procurement. A cleaned and inspected unit is not the same as a serviced unit. If a full engineer service and calibration has been carried out, the listing should state this explicitly, including what was done and by whom.
The Elengeza range has been produced in more than one configuration. Specifications published for one generation do not necessarily apply to another. Confirm the exact model designation, Linet part number or serial prefix before comparing specifications or ordering replacement parts. Do not rely on generic Elengeza data sheets without verifying the model matches the unit offered.
Check that handset cables, motor actuators and control boards are still available from Linet or an approved parts distributor for the specific model generation. On older units, parts availability can be limited, which affects the total cost of ownership and ease of maintenance.
Confirm mains voltage and plug format. If nurse call or bed-exit alarm integration is required, check whether the bed carries the appropriate socket and whether the protocol is compatible with the ward system in use. These integrations are site-specific and are not verified by the supplier.
The following points cover the most important factors to assess.
For any detail not covered in the listing, ask before ordering. Photographs form part of the description on pre-owned units and should be reviewed carefully before purchase.
![]() |
Ready to move forward with the Linet Elengeza Electric Hospital Bed with Controllers and Mattress? Shop the Linet Elengeza Electric Hospital Bed with Controllers and Mattress |
Lämna en kommentar