Alvera AquaPure 10 Humidifier Water Chamber for AirSense 10, AirCurve 10 and Lumis Machines
£26.99
This item
The water chamber is the part of a humidified setup that holds standing water, heats every night, and is handled twice a day. It is a consumable, not a permanent fitting, and it is the component whose condition most directly affects how well humidification works. A chamber that has clouded, scaled or developed a tired seal delivers less moisture than it did when new and leaks around the base plate as it ages. Because the decline is gradual, most wearers turn the humidity setting up rather than change the chamber, which masks the problem instead of fixing it. AquaPure 10 is a compatible chamber for the Air 10 platform, covering AirSense 10 and AirSense 10 Elite, AirCurve 10 and Lumis series machines.
What is included| Item | Detail | Condition |
|---|---|---|
| AquaPure 10 water chamber | One compatible humidifier water chamber for Air 10 platform machines, REF 56010 | NEW |
What is not included| Item | Detail | Status |
|---|---|---|
| Therapy machine | Air 10 platform machine with its built-in humidifier | SOLD SEPARATELY |
| Heated tubing | Heated tube for climate controlled humidification | SOLD SEPARATELY |
| Standard tubing | Unheated 19 mm or 15 mm hose | SOLD SEPARATELY |
| Mask and headgear | Any interface | SOLD SEPARATELY |
| Machine filters | Air inlet filters | SOLD SEPARATELY |
| Distilled water | Required to fill the chamber | SOLD SEPARATELY |
Distilled water only, and fill to the line
When a chamber needs renewingWater chambers do not fail suddenly. They degrade, and the symptoms get attributed to something else.
Clouding and scale. A chamber that has gone milky, or that has a white film on the base plate, is transferring heat less efficiently than a clear one. The heater works harder and delivers less humidity for the same setting.
A tired seal. The seal around the lid and the base compresses over months of daily handling. Once it stops sealing cleanly the chamber leaks air, which the machine reads as circuit leak, and it can leak water onto the bedside table.
Cracking and crazing. Fine cracks appear around the fill line and the corners first, usually from thermal cycling and from being washed too hot. A cracked chamber must come out of service.
Rising humidity settings. If the setting that used to be comfortable no longer is, and the tubing and mask are unchanged, the chamber is usually the reason.
Check the machine before ordering
This chamber fits Air 10 platform machines: AirSense 10 and AirSense 10 Elite, AirCurve 10 and Lumis series devices, all of which share the same humidifier bay. It does not fit AirSense 11 or AirCurve 11 machines, which take a different chamber, and it does not fit AirMini machines, which use waterless humidification and have no chamber at all. The machine model is printed on the underside of the device. Air 11 platform owners need AquaPure 11, REF 56011.
| Brand | Alvera |
| Product | AquaPure 10 humidifier water chamber |
| Reference | 56010 |
| GTIN | 5065027735408 |
| Pack size | 1 |
| Product type | Compatible humidifier water chamber, third party accessory |
| Fits | AirSense 10, AirSense 10 Elite, AirCurve 10 and Lumis series machines |
| Does not fit | AirSense 11, AirCurve 11 and AirMini machines |
| Water | Distilled water only |
| Fitting | Lifts in and out of the humidifier bay, no tools |
| Supplied | Non-sterile, single patient use |
| Condition | New |
Specification limited to what is confirmed
Capacity, material, dishwasher suitability and service life are not stated here pending confirmation against the production record, and should not be assumed from the description above. Dishwasher suitability in particular varies between chambers, so the instructions supplied with this chamber govern how it is cleaned. Ask before ordering if any of these details is needed.
| Action | Detail | Interval |
|---|---|---|
| Empty and refill | Empty any remaining water, rinse, and refill with fresh distilled water to the fill line | Daily |
| Wash | Wash in warm water with a mild detergent, rinse thoroughly and air dry away from direct sunlight | Weekly |
| Inspect | Check for clouding, scale on the base plate, cracks around the fill line and a seal that no longer sits flat | Weekly |
| Check the seat | Confirm the chamber seats fully in the bay and the machine does not report a leak | Weekly |
| Before travel | Empty and dry the chamber completely before the machine is moved or packed | Every journey |
| Renew | Fit a fresh chamber when it clouds, scales, cracks, leaks or no longer holds its seal | Typically every six to twelve months |
The above is general guidance for a single user. The instructions supplied with the machine and with the chamber take precedence. Do not use bleach, alcohol-based cleaners, chlorine, aromatic solvents or moisturising soaps on a water chamber.
Alvera is the own-brand accessory range from Elarix Medical, covering the consumables that sleep therapy depends on and that need renewing on a schedule. AquaPure covers humidifier water chambers, alongside PureFlow machine filters, PureGuard in-line bacteria filters, AirGuard filter covers, AirLink connectors and adapters, AirStrap headgear and clips, ThermaAir heated tubing, AirFlex tubing, AirSoft cushions and PureWipe cleaning wipes. Products are individually referenced and barcoded, so a repeat order is placed against a code rather than a description.
Specifications can change without notice. Ask us for the current technical file.
UK mainland: Orders placed before 1pm Monday to Friday are dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland and islands: standard delivery takes 1 to 3 working days.
Europe, USA and Canada: delivery typically takes 1 to 3 working days.
Other international destinations: delivery usually takes 5 to 7 working days.
Orders shipped outside the United Kingdom may attract import duty and local tax, which are charged by the destination country and are the buyer's responsibility.
SelfiMed offers a 30-day change-of-mind return policy on eligible items. To request a return, please contact us within 30 days of delivery. Items returned under this policy must be in the same condition as received and suitable for resale.
Please note that brand new items must remain unopened, unused and in their original packaging to be eligible for return. Once a new item has been opened or used, it may no longer qualify for return as new, and any accepted return may be subject to restocking fees.
For hygiene reasons, opened CPAP masks, CPAP parts and CPAP accessories, including tubing, filters and humidifier chambers, cannot be returned.
Return shipping costs are the responsibility of the customer.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Specifications and compatibility are given in good faith and can change without notice.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article