The Labcold Benchtop Intellicold Pharmacy Fridge is a compact, purpose-built refrigeration unit designed for the storage of pharmaceuticals, vaccines and temperature-sensitive clinical stock in pharmacy, dispensary and clinical department settings. Purchasing a refurbished unit offers a practical route to compliant cold-chain storage at reduced cost, provided the unit is correctly set up, maintained and monitored from the outset.
A Labcold Benchtop Intellicold Pharmacy Fridge supplied as refurbished, also described as pre-owned, will have been cleaned and inspected before dispatch. In-house checks typically cover power-on function, temperature stability and door seal integrity. These are workshop-level checks. They do not constitute a full engineer service or calibration unless the listing explicitly states otherwise.
Photographs form part of the description. Review them carefully for cosmetic condition, shelf configuration and any accessories shown. If the photographs do not match your requirements, ask before ordering.
Refurbished units are commonly supplied with the fridge body, internal shelving and a power lead. Items that may not be included are:
Confirm the exact contents with the supplier before purchase. Do not assume accessories are present unless they appear in the included items table or are confirmed in writing.
Planned maintenance, periodic electrical safety testing (PAT) and any formal calibration remain the responsibility of the receiving organisation. The in-house dispatch check does not transfer or replace these obligations. Organisations operating under pharmacy or clinical governance frameworks should schedule these checks according to their own protocols and the manufacturer instructions, whichever is the more stringent.
![]() |
Labcold Benchtop Intellicold Pharmacy Fridge - Refurbished £399.99 Buy nowView product |
The benchtop form factor is compact and straightforward to position, but ventilation clearance is critical to stable temperature performance. Follow the manufacturer instructions for minimum clearances at the rear and sides. Placing the unit in an enclosed cupboard or against a heat source will impair cooling efficiency and may cause the unit to operate outside its target range.
Site the fridge on a stable, level surface. Uneven positioning affects door alignment and door seal performance over time.
Allow the unit to reach its set temperature before loading any stock. This typically takes several hours after first power-on. Load only after the display confirms the internal temperature is stable and within the target range specified for the stored products. Do not load warm stock in bulk immediately after a temperature excursion or after the unit has been off for transport.
Pharmacy refrigerators are generally set to store products in the range of 2 to 8 degrees Celsius. Verify the actual internal temperature using a calibrated independent probe or data logger, not solely the unit display. The display reflects the sensor reading; a secondary verified measurement confirms the actual storage environment. Record this verification as part of your commissioning protocol.
Continuous or twice-daily manual temperature monitoring is standard practice in regulated pharmacy environments. The Intellicold range includes integrated temperature management features, including audible and visual alarms for excursions. Confirm that alarms are active and that alert thresholds are set correctly for your stored products.
An external data logger provides an independent, time-stamped record suitable for audit and compliance purposes. This is sold separately and is strongly recommended for environments subject to regulatory inspection.
Avoid overloading the cabinet. Adequate airflow around stored items is necessary for uniform temperature distribution. Rotate stock consistently, placing newer stock behind existing stock. Do not store non-pharmaceutical items in a pharmaceutical fridge.
Establish a written alarm response protocol before the unit goes into service. This should define who responds, the acceptable time window for response, what constitutes a reportable excursion and the escalation path if the fault cannot be resolved promptly. Stock disposition decisions following a temperature excursion must follow your organisation's clinical or pharmacy governance procedures, not the fridge manufacturer's guidance alone.
Clean the internal surfaces and shelves regularly using a mild detergent solution compatible with food-contact and clinical environments. Disconnect power before cleaning. Allow all surfaces to dry fully before reconnecting and reloading. Do not use abrasive cleaners or spray directly onto the control panel or display.
Clean the door gasket regularly. A damaged or compressed gasket impairs the door seal and allows warm air ingress, which affects temperature stability. If the gasket is visibly deformed or no longer seals cleanly, replace it. Replacement gaskets are a consumable item and are available separately.
Some benchtop pharmacy fridges require periodic manual defrosting if frost builds up on the rear wall or evaporator plate. Excessive frost reduces cooling efficiency. Follow the manufacturer instructions for defrost frequency and procedure. Record each defrost as part of your maintenance log.
Portable appliance testing (PAT) must be carried out at intervals determined by the operating organisation's risk assessment and local policy, in line with the requirements of PUWER 1998. A pre-owned unit should be PAT tested by a competent person before it enters service. Do not assume the dispatch check covers this obligation. The testing interval and records remain with the operating organisation.
A refurbished Labcold Benchtop Intellicold Pharmacy Fridge offers a practical, lower-cost route to pharmaceutical cold-chain storage. To get the most from it, commission it correctly before loading stock, verify the temperature independently, establish a written alarm response protocol and schedule planned maintenance from the outset. The in-house dispatch checks confirm the unit is functional, but ongoing compliance, calibration and electrical safety testing are the responsibility of the operating organisation. Where uncertainty exists about included accessories, compatibility or service history, ask before ordering.
![]() |
Ready to move forward with the Labcold Benchtop Intellicold Pharmacy Fridge - Refurbished? Shop the Labcold Benchtop Intellicold Pharmacy Fridge - Refurbished |
SelfiMed UK
BLACK FRIDAY
+ up to −80% on selected items, no code needed
Join our list for deal alerts, restocks and CPAP tips. Your code appears straight away.
Free UK mainland delivery over £300 · next-day dispatch before 1pm
By signing up you agree to receive marketing emails from SelfiMed UK. Unsubscribe at any time. Code valid on all products until Monday 30 November 23:59. One discount per item: items already at −50% or −80% keep that deal instead.
It's already in your basket, so 10% comes off at checkout.
Valid on all products. One discount per item. Ends Monday 30 November 23:59.
Dejar un comentario