Chat disponível 24/7
Chat disponível 24/7
The ResMed AirFit™ P10 Mask Kit for AirMini™ User is a nasal pillow interface designed specifically for use with the ResMed AirMini™ travel CPAP device. It differs from the standard AirFit P10 in one important way: it integrates directly with the AirMini™ system, omitting the standard 22 mm elbow and replacing it with an AirMini-compatible connector. Buyers regularly arrive with the same set of questions before ordering, so the following sections address those directly and plainly.
ResMed markets this product as a kit rather than a complete mask assembly. The kit typically includes the AirFit P10 frame, two sizes of nasal pillow cushion (small and medium, or small, medium and large depending on pack variant), headgear and the AirMini-specific HumidX or HumidX Plus waterless humidification module. Buyers should confirm the exact contents against the product listing and packing slip, because kit composition has varied between catalogue revisions.
The AirMini™ device itself is sold separately. Standard 22 mm tubing is not compatible and is not included. A water chamber is not part of this interface system because the AirMini™ uses the HumidX module for humidification rather than a heated water circuit. If your AirMini™ unit did not ship with a mask kit, the kit is ordered independently.
This kit is designed exclusively for the AirMini™. The AirMini-specific connector on the frame is not interchangeable with the standard AirFit P10 for Her or the standard AirFit P10 sold for full-size ResMed devices. Using an incompatible interface with the AirMini™ will prevent a correct seal and may affect therapy delivery. Ask before ordering if you are uncertain which variant you need.
![]() |
ResMed AirFit™ P10 Mask Kit for AirMini™ User £142.99 Buy nowView product |
The AirFit P10 frame uses small integrated magnets to allow the headgear to detach and reattach quickly at the sides of the frame. This is a convenience feature that simplifies nightly fitting and removal throughout the night if the user needs to get up. The magnets are located in the frame clips, not in the cushion or headgear strap itself.
The magnetic clips present a risk to anyone with a pacemaker, implantable cardioverter-defibrillator, neurostimulator, adjustable CSF shunt valve, aneurysm clip, metallic stent, cochlear implant, insulin pump or other ferromagnetic implant. This applies to the wearer, the bed partner and anyone handling the mask. If any of these devices or implants are present, do not use or handle this mask without first consulting a qualified clinician and the implant manufacturer.
Keep the mask away from other magnetic devices, credit cards with magnetic strips and electronic components that are sensitive to magnetic fields. The magnets are small but sufficient to affect nearby items if stored in close contact.
The AirMini™ system does not use a traditional heated humidifier water chamber. Instead, it relies on a heat and moisture exchanger (HME) in the form of the HumidX or HumidX Plus module. This module sits inside the AirMini-specific mask connector and captures exhaled moisture, returning it to the incoming airflow on the next breath. The result is passive humidification without tubing, a water chamber or heated tubing.
The HumidX module is a consumable. ResMed specifies a replacement interval: the module should be replaced after 30 days of nightly use. It is not reusable indefinitely and performance degrades with continued use. Replacement modules are available separately. Photographs of the module condition, where provided in the listing, form part of the description.
The HumidX Plus is rated for a higher humidity output than the standard HumidX. Neither module produces the humidification levels achievable with a full heated humidifier and heated tubing. Users who require high humidification levels, for example those with significant nasal dryness, should discuss module selection with their prescribing clinician before ordering.
The nasal pillow cushion must seal at the nares without pressing the septum or collapsing. ResMed supplies a sizing guide with the kit. Sizing is based on the width of the nares, not on general face size. Most kit variants include multiple cushion sizes to allow fitting at home without a clinic visit, though a clinic fitting is preferable when therapy is first prescribed.
Mouth breathing throughout the night reduces the effectiveness of a nasal pillow interface because air escapes via the mouth. If mouth breathing is a consistent pattern, a full face mask or a chin strap may be more appropriate. Ask your prescribing clinician before ordering if mouth breathing is a known issue.
Cushions are single-use consumables rated for approximately 30 days of nightly use. Headgear typically requires replacement at six months. The frame is replaced at six to twelve months depending on condition. These are general guidance intervals; manufacturer instructions take precedence and should be consulted directly.
New kits are supplied in original ResMed packaging with full component sets. Pre-owned interfaces raise hygiene and consumable concerns: a used cushion must not be reused by a different patient. Any pre-owned mask frame should be decontaminated according to a documented protocol before reuse. Consumable components including cushions and HumidX modules should be treated as single-use and replaced before first use by a new patient. Photographs form part of the description for pre-owned listings.
CPAP therapy, including the mask interface, is a prescribed therapy in most clinical pathways. The mask selection should be agreed with the prescribing clinician or sleep service. Compliance data recorded by the AirMini™ device reflects mask performance alongside device settings; a poor-fitting interface will appear in nightly usage data as leak events.
If you are unsure whether your AirMini™ unit requires the AirMini-specific kit or a standard AirFit P10 variant, confirm the device model and check the AirMini compatibility list before ordering. The connector design is not interchangeable. Part numbers and GTINs for each kit variant are listed on the ResMed website and should be matched to your device before purchase.
The ResMed AirFit™ P10 Mask Kit for AirMini™ User is a nasal pillow interface kit built specifically for the AirMini™ travel CPAP device. It includes frame, cushions in multiple sizes, headgear and the HumidX waterless humidification module. It is not compatible with standard full-size ResMed devices or standard 22 mm tubing. The magnetic frame clips are a contraindication for certain implanted devices: check before handling. Consumable components including cushions and HumidX modules have defined replacement intervals and are not indefinitely reusable. Sizing requires matching cushion size to nares width, and mouth breathing reduces suitability. For pre-owned units, decontamination of the frame and replacement of all consumables are required before patient use. Confirm compatibility with your specific AirMini™ model before ordering.
![]() |
Ready to move forward with the ResMed AirFit™ P10 Mask Kit for AirMini™ User? Shop the ResMed AirFit™ P10 Mask Kit for AirMini™ User |
SelfiMed UK
BLACK FRIDAY
+ up to −80% on selected items, no code needed
Join our list for deal alerts, restocks and CPAP tips. Your code appears straight away.
Free UK mainland delivery over £300 · next-day dispatch before 1pm
By signing up you agree to receive marketing emails from SelfiMed UK. Unsubscribe at any time. Code valid on all products until Monday 30 November 23:59. One discount per item: items already at −50% or −80% keep that deal instead.
It's already in your basket, so 10% comes off at checkout.
Valid on all products. One discount per item. Ends Monday 30 November 23:59.