A Seers Medical 3 Section Electric Examination table is a powered height-adjustable couch designed for clinical assessment, minor procedures and patient positioning in ward, theatre and outpatient settings. Understanding what to evaluate before purchasing, whether new or pre-owned, helps ensure the unit is fit for its intended environment and compliant with relevant workplace regulations.
The frame should be inspected for structural soundness. Look for signs of weld fatigue, corrosion at joints or deformation along the base rails. On a used unit, ask the seller whether the item has been cleaned, inspected and function tested before dispatch.
The three-section layout typically comprises a fixed base section, a backrest and a leg rest. Confirm that all three articulate independently and that the locking mechanisms engage positively at each preset angle.
Upholstery on a pre-owned unit should be assessed closely. Look for tears, compression damage or degradation of the foam core. Damaged upholstery is not straightforward to decontaminate to the required protocol standard and may need replacement before the table is placed in service.
Confirm that all castors roll freely and that the brake engages on each wheel. A table that does not lock securely in position is not safe for use. On wheeled models, check that the central locking pedal, where fitted, holds the table static under lateral load.
![]() |
Seers Medical 3 Section Electric Examination Couch with Controller £699.99 Buy nowView product |
The electric drive raises and lowers the platform height and, depending on the model, adjusts individual sections. Test the full range of travel in both directions. Listen for abnormal noise from the actuator, which can indicate wear or inadequate lubrication. Confirm the unit reaches its stated minimum and maximum heights.
The handset should be present and functional. Missing or damaged handsets may be available separately, but compatibility must be confirmed against the specific model and serial number before ordering. Ask before ordering if the listing does not specify the handset status explicitly.
Check each button for positive action and confirm that the table responds without delay or intermittent failure. On used units, worn or sticky controls are a common fault and are not always cosmetic.
Many Seers Medical electric tables incorporate an anti-trap or safety stop function on the height drive. Confirm this feature is present and operational. A table dispatched without a verified safety stop check should not be placed directly into a clinical environment without independent assessment.
Any electrically powered medical device used in a clinical setting must be subject to periodic electrical safety testing. Ask the seller for the most recent portable appliance test record. If no record is available, the operating organisation is responsible for arranging testing before the unit is placed in service.
Under the Provision and Use of Work Equipment Regulations 1998 (PUWER), the employer is responsible for ensuring that work equipment, including powered examination tables, is maintained in a safe condition, inspected at suitable intervals and used only by people who have received adequate training. A pre-owned table does not arrive with a clean compliance record. The receiving organisation must establish its own inspection and maintenance schedule from the point of receipt.
Confirm that the serial number is legible and recorded. Request any available service history, user manual or manufacturer documentation. Where documents are not supplied with the unit, note that the operating organisation will need to source these independently before commissioning.
Every examination table carries a stated safe working load (SWL). Confirm this figure against the patient population the table will serve. On a pre-owned unit, the SWL stated by the seller should match the manufacturer's published specification for that model. Do not accept a figure that cannot be verified against the serial number or original documentation.
Where accessories such as arm rests, footrests or stirrups are in use, confirm that their combined weight does not reduce the effective SWL below what the clinical use requires. Some accessories are sold separately and are not included as standard. Ask before ordering if the listing is not explicit.
Structural damage, weld repair or modification to the frame may affect the original load rating. A unit that has been modified must be assessed by a competent person before a load capacity is assigned. Do not assume the original SWL applies to a modified frame.
Evaluating a Seers Medical 3 Section Electric Examination table requires attention across several areas. The points below summarise what a competent buyer should confirm before placing an order or placing a unit into service.
![]() |
Ready to move forward with the Seers Medical 3 Section Electric Examination Couch with Controller? Shop the Seers Medical 3 Section Electric Examination Couch with Controller |
Deixe um comentário