This item
The Arjo Sara Stedy is a non-powered stand and transfer aid for patients who can bear weight and rise from sitting with some support. The patient stands on the platform holding the central frame, the seat paddles fold down behind them to take their weight in a semi-sitting position, and the carer moves the unit a short distance to a bed, chair, toilet or basin.
This Sara Stedy does not have a leg spreader. The base does not open to widen around a chair or commode. Please check the images and this description carefully before purchasing to confirm this configuration suits the setting it is intended for. Once the item has shipped, the refund covers the cost of the product, and the cost of returning it is paid by the buyer.
What the Sara Stedy does well is keep the patient working. A wheelchair transfer asks nothing of the patient, and a hoist takes over the movement entirely. The Sara Stedy asks the patient to stand and hold on, which maintains leg strength and confidence, while the frame and the seat paddles make it safe for the carer to support them. Because the patient stands at the carer's height, the transfer happens face to face and at eye level, which matters for communication and dignity during toileting and personal care.
At around 20 to 22 kg it is light enough to move between rooms and to store without a dedicated space, and its safe working load of 182 kg covers a wide range of patients. It is used in hospitals, rehabilitation wards, nursing and residential homes, and community and home care.
| Item | Detail |
|---|---|
| Manufacturer | Arjo, formerly ArjoHuntleigh |
| Product | Sara Stedy stand and transfer aid |
| Model | NTA1000 |
| Configuration | Fixed base, no leg spreader |
Patient selection. The Sara Stedy is for patients who can bear weight through their legs, hold the frame and rise from sitting with support. It is not suitable for a patient who cannot stand, cannot hold on, or cannot follow simple instruction, and for them a hoist is the appropriate equipment. It is a transfer aid for short distances, not a walking aid and not a means of transporting a patient between rooms or along corridors. Selection is a clinical decision recorded in the patient's moving and handling assessment.
Safe use. The patient stands on the platform with both feet placed before the seat paddles are lowered, and the paddles are raised only once the patient is standing securely. Apply the brakes before the patient stands or sits, and whenever the unit is stationary. Move the Sara Stedy slowly on level floors and avoid thresholds, slopes and uneven surfaces with a patient on board. Do not exceed the safe working load of 182 kg, and read the figure on this unit's own label before use.
Condition and inspection. This unit is pre-owned and supplied without a service history. Check the frame, platform, seat paddles, handles, castors and brakes for damage before first use, and carry out routine inspection to the manufacturer's instructions and local policy thereafter. Duties under PUWER 1998 apply to equipment used at work. Clean between patients with a disinfectant compatible with the frame and grips.
Specifications can change without notice. Ask us for the current technical file.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Meical Equipment Advice and Guidance
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Read Article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Read Article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Read Article