Chat disponível 24/7
Chat disponível 24/7
Usado
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
VAT relief applied — no VAT will be charged at checkout.
Free UK mainland delivery on orders over £1,000
Adicione o conjunto completo de uma só vez.
The RSBG1030MD is Labcold's compact blood bank refrigerator, 88 litres and holding around thirty 250 ml blood bags, running at 4 degrees Celsius with a seven day chart recorder and a full alarm set. It is a benchtop sized cabinet at 490 mm wide, which is what makes it the unit for a satellite fridge sited where blood is actually needed rather than only in the transfusion laboratory.
The difference between this and a pharmacy refrigerator is the way temperature is measured, and it is not a detail. A pharmacy or domestic cabinet reads the air inside the chamber, and air changes temperature the instant a door opens. A blood bank refrigerator reads a liquid load simulator as well: a sealed container of fluid chosen to match the thermal mass of a blood bag, so the figure on the display tracks what the blood is doing rather than what the air is doing. This cabinet shows both the chamber and the liquid load simulator on its touch panel, which is the measurement that actually matters when the door has just been opened twice in a minute.
NHSBT specify that red cells are stored at 4 degrees Celsius plus or minus 2, in an approved blood refrigerator fitted with a temperature recorder and an alarm. This cabinet is built to that requirement: a seven day chart recorder, an adjustable audible alarm, a core temperature action alarm, remote alarm contacts for connection to a building management or on-call system, and a blood audit interface. Storage of blood for transfusion in the United Kingdom falls under the Blood Safety and Quality Regulations 2005, and the cabinet is certified as a medical device and built to BS 4376 Part 1.
The practical case for a small cabinet of this kind is the thirty minute rule. A unit of red cells that spends more than thirty minutes out of controlled storage cannot simply go back into the issue fridge, and beyond sixty minutes it is a quarantine question. A compact blood bank refrigerator close to theatre, to the emergency department or to a remote issue point keeps that clock short. The glass door with clear inner doors lets stock be counted without opening the chamber, which is itself a thermal event, and the keypad lock controls who gets into it.
| Model | RSBG1030MD |
| Brand | Labcold |
| Product | Compact blood bank refrigerator |
| Capacity | 88 litres |
| Blood bag capacity | Around 30 bags at 250 ml |
| Door | Glass, with clear inner doors |
| Solid door equivalent in the Labcold range | RSBB prefix, a separate model |
| Operating temperature | 4 degrees Celsius |
| Recorder | Seven day chart recorder |
| Condition | Pre-owned |
Points to note before ordering
As especificações podem mudar sem aviso prévio. Peça-nos o ficheiro técnico atual.
Documentação adicional disponível mediante pedido.
As encomendas efetuadas antes das 13:00, de segunda a sexta-feira, são expedidas no mesmo dia útil a partir de Leeds. As entregas são feitas de segunda-feira a sábado, nunca ao domingo.
Reino Unido continental, artigos leves: 1 a 2 dias úteis. Artigos pesados e volumosos: 2 a 4 dias úteis.
As encomendas internacionais são enviadas na modalidade entregue no local (DAP). Os direitos de importação, os impostos locais e as taxas de desalfandegamento são cobrados pelo país de destino e são da responsabilidade do comprador.
Os artigos por abrir podem ser devolvidos no prazo de 30 dias após a entrega. Informe-nos antes de enviar qualquer artigo, para que lhe possamos fornecer uma referência de devolução.
Por razões de higiene, os artigos abertos que entram em contacto com as vias respiratórias não podem ser devolvidos, exceto se tiverem defeito.
Ler a política de devoluções completa
Isto não afeta os seus direitos legais.
Os reembolsos são efetuados para o método de pagamento original assim que o artigo devolvido nos chega e é verificado, normalmente no prazo de cinco dias úteis.
Os artigos com defeito são reembolsados na totalidade, incluindo os portes de envio que pagou.
As informações desta página são fornecidas a título indicativo e não substituem o aconselhamento de um profissional de saúde qualificado. Leia sempre as instruções do fabricante antes da utilização e verifique se o dispositivo é adequado ao doente e à terapia prescrita.
Segue na mesma encomenda.
Mais na mesma categoria.
Continue de onde parou.
Written by people who bought from us.
Aconselhamento e orientação sobre equipamento médico
October 04, 2026
The Alvera AirLink 360 Swivel is a 360-degree rotational CPAP connector that reduces tubing drag and helps maintain mask seal throughout ...
Ler artigo
October 04, 2026
An honest pre-purchase guide to the Alvera AirLink Mini Mask Adapter Twin covering compatibility, included items, cleaning and clinical u...
Ler artigo
October 04, 2026
Avoid the most common fitting, replacement and compatibility mistakes with the ALVERA PureGuard™ Universal In-Line Bacteria Filter. Pract...
Ler artigo