Salt la conținut
VAT Relief available for eligible patients — save 20% on your order
Expediere a doua zi pentru comenzile plasate înainte de ora 13:00, de luni până vineri
Livrare în întreaga lume cu transportatori de încredere — cu urmărire și asigurare
Livrare gratuită în Regatul Unit peste £300 · produse mari £1,000+
ResMed ClimateLineAir 10 Heated Tube -Ref 37298 heated cpap tube SelfiMed UK

ResMed ClimateLineAir 10 Heated Tube: The Questions Buyers Ask Before Ordering

The ResMed ClimateLineAir 10 Heated is a heated tubing accessory designed for use with AirSense 10 and AirCurve 10 series devices. It integrates with the device's climate control system to maintain consistent air temperature and humidity throughout the night, reducing the likelihood of rainout and condensation in the circuit. Before ordering, buyers typically have specific questions about compatibility, included items, condition and ongoing maintenance. This article addresses those questions directly.

What the ResMed ClimateLineAir 10 Heated Actually Is

The core function

The ClimateLineAir 10 Heated is a 1.9-metre heated tube. It connects the AirSense 10 or AirCurve 10 device to the interface, replacing a standard unheated tube. The tube contains a heating element that works in conjunction with the device's integrated humidifier and the ClimateControl or AutoSet algorithms to regulate delivered air temperature in response to ambient conditions.

How it differs from a standard tube

A standard 22 mm tube carries air but applies no heat. Condensation can form when warm humidified air meets a cooler tube wall, producing rainout. The heated tube maintains the air column at a set temperature, which reduces condensation along the circuit. This is relevant nightly in cold rooms or where the device sits some distance from the user.

What it is not

The ClimateLineAir 10 Heated is a tubing accessory. It is not a complete therapy setup. The device, water chamber, mask, cushion, headgear and air filter are all sold separately. The tube alone does not deliver therapy.

ResMed ClimateLineAir 10 Heated Tube -Ref 37298 heated cpap tube SelfiMed UK

ResMed ClimateLineAir 10 Heated Tube -Ref 37298

£38.99

Buy nowView product

Compatibility: Checking Before You Order

Device compatibility

The ClimateLineAir 10 Heated is compatible with the following ResMed platforms:

  • AirSense 10 AutoSet, including the AutoSet for Her variant
  • AirSense 10 Elite, the fixed-pressure variant
  • AirSense 10 CPAP, the basic fixed-pressure model
  • AirCurve 10 VAuto, S and ASV, the bilevel range

It is not compatible with AirSense 11, S9 series or any third-party device. The connector profile and communication protocol are specific to the AirSense 10 and AirCurve 10 platforms. Ask before ordering if you are uncertain of your device generation.

Mask and interface compatibility

The tube connects to the mask elbow or interface using a standard 22 mm fitting at the patient end. It is compatible with full face, nasal and nasal pillow interfaces. The heated element runs to the patient end of the tube. The mask, cushion and headgear are not included and must be sourced separately.

Water chamber requirement

The ClimateLineAir 10 Heated requires a compatible water chamber to function as intended. Without a filled and seated water chamber in the device, the heated tube provides air delivery but no humidification. The water chamber is not included with the tube and is sold separately. Confirm chamber compatibility with your specific device model before ordering.

What Is and Is Not Included

What the tube listing typically covers

When the ClimateLineAir 10 Heated is listed as a standalone item, it typically includes:

  • Heated tube, 1.9 metres, with integrated heating element
  • Device-end connector, specific to AirSense 10 and AirCurve 10
  • Patient-end connector, standard 22 mm fitting

What is not included

The following items are not included unless explicitly stated in the listing:

  • CPAP or bilevel device, sold separately
  • Water chamber, sold separately, required for humidification
  • Mask, cushion and headgear, sold separately
  • Air filter, sold separately, a consumable requiring periodic replacement
  • Power supply, belongs to the device, not the tube

Photographs form part of the description. Review all listing images before ordering to confirm the contents.

Condition, Maintenance and Replacement Intervals

New versus pre-owned

The ClimateLineAir 10 Heated is available as new and, in some listings, as pre-owned or used. A new tube is supplied in original ResMed packaging. A pre-owned tube will have been cleaned and inspected before dispatch. Condition is stated explicitly in the listing and on each line item. Ask before ordering if condition is not clearly stated.

Cleaning and care

ResMed classifies the ClimateLineAir 10 Heated as a single-patient consumable intended for periodic replacement rather than indefinite reuse. Routine care includes:

  • Daily inspection, check for condensation, kinks or visible damage
  • Weekly cleaning, disconnect from device and mask, hand wash in warm water with mild detergent, rinse thoroughly, hang to air dry away from direct sunlight
  • Do not submerge the connectors, the electrical contacts at the device end must remain dry
  • Do not use bleach or alcohol-based cleaners, these degrade the tube material and heating element over time

Manufacturer instructions take precedence over general guidance. Refer to the ResMed ClimateLineAir 10 user guide for the current cleaning protocol.

Replacement intervals

ResMed recommends replacing the heated tube at least every twelve months under nightly use. In practice, the tube should be replaced sooner if the heating element fails, the tube becomes discoloured, cracked or kinked, or if condensation management deteriorates noticeably. Compliance with replacement intervals supports consistent humidification performance throughout the night.

Practical Considerations Before You Buy

Travel and portability

The ClimateLineAir 10 Heated is 1.9 metres in length and adds marginal weight compared to a standard tube. It is compatible with the AirSense 10 travel setup. Some travel power supplies do not support the heated tube function. Confirm power compatibility before travelling, particularly with 12V DC adapters.

Noise and condensation management

Rainout produces an audible gurgling sound in the circuit and can disrupt sleep onset. The heated tube is the primary intervention for users who experience this with a standard tube and humidifier. If rainout persists with the heated tube in place, check room temperature, humidity settings and whether the water chamber is correctly seated and filled.

Ordering the right part number

ResMed lists the ClimateLineAir 10 Heated under part number 37298. Confirm the part number before ordering, particularly when sourcing from third-party suppliers or purchasing pre-owned stock. The AirSense 11 uses a different heated tube that is not backward compatible.

Summary

The ResMed ClimateLineAir 10 Heated is a purpose-built heated tube for AirSense 10 and AirCurve 10 devices. It manages condensation throughout the night by maintaining air temperature along the circuit in response to ambient conditions. Compatibility is limited to the AirSense 10 and AirCurve 10 platforms. The tube is a consumable, sold separately from the device, water chamber and mask. Condition should be stated clearly in any listing. Replace at least annually under nightly use, or sooner if performance or physical condition declines. Ask before ordering if any detail is unclear.

ResMed ClimateLineAir 10 Heated Tube -Ref 37298 heated cpap tube SelfiMed UK

Ready to move forward with the ResMed ClimateLineAir 10 Heated Tube -Ref 37298?

Shop the ResMed ClimateLineAir 10 Heated Tube -Ref 37298
Articolul anterior When to Replace Your Welch Allyn CP 150 ECG Machine: Signs to Watch For
Articolul următor ResMed S10 HumidAir Standard Tub: How to Choose and What to Expect

Lăsați un comentariu

* Câmpuri obligatorii