Chat disponibil 24/7
Chat disponibil 24/7
Second-hand
−10%at checkout · BLACKFRIDAY10
Black Friday · ends Monday 30 November, 23:59
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
−10%at checkout · BLACKFRIDAY10
Black Friday · ends Monday 30 November, 23:59
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
VAT relief applied — no VAT will be charged at checkout.
✓ FREE UK mainland delivery on this item
Adăugați întregul set dintr-o dată.
An Exergen calibration verification kit, part 129062, supplied with four TemporalScanner infrared temporal artery thermometers: two of the current TAT-5000S and two of the preceding TAT-5000. The kit holds a certified master reference thermometer, a portable handheld blackbody target and a mains supply with international adapter blades, in a rugged case, and it verifies thermometers against the master on the bench rather than sending them away.
This is what turns a set of thermometers into a managed estate. A clinical thermometer is a measuring instrument, and an instrument whose accuracy nobody has checked is an instrument nobody should be charting from. Exergen's answer is a portable blackbody held at body temperature, between 36 and 40 degrees Celsius, and a certified master thermometer kept alongside it. Both the master and the instrument under test read the same target in turn, and the two figures are compared. A TAT-5000 or TAT-5000S passes if it agrees with the master within 0.2 degrees Celsius.
The procedure is deliberately undramatic, which is why a ward can run it. The verifier warms up for about five minutes, the thermometers sit in the same room for at least ten so everything is at one temperature, every lens including the master's is wiped with an alcohol swab, and readings are then taken alternately. On a large batch the master is re-read about every ten instruments so its own drift does not go unnoticed. Exergen note that a dirty lens is the commonest cause of a low reading, so a cleaning and a repeat comes before any conclusion that an instrument has failed.
The kit covers the whole TemporalScanner family rather than one generation, which is why a mixed set like this one works with it: Exergen list the TAT-2000, TAT-2000C, TAT-5000 and TAT-5000S as applicable models. The two TAT-5000S units are the current generation, released as the successor to the TAT-5000 with the same stated accuracy and a revised housing, and all four read to 0.1 degrees Celsius with a clinical accuracy of plus or minus 0.1 degrees Celsius to ASTM E1112.
| Brand | Exergen |
| Kit | Calibration verification kit, part 129062 |
| Thermometers supplied | Two TemporalScanner TAT-5000S and two TemporalScanner TAT-5000 |
| Verification principle | Comparison against a certified master reading a blackbody target |
| Blackbody target range | 36 to 40 degrees Celsius |
| Pass tolerance for the 5000 series | Within 0.2 degrees Celsius of the certified master |
| Applicable models | TAT-2000, TAT-2000C, TAT-5000 and TAT-5000S |
| Thermometer accuracy | Plus or minus 0.1 degrees Celsius, to ASTM E1112 |
| Condition | Pre-owned |
Points to note before ordering
Exergen calibrate these instruments two ways, arterial and oral equivalent, and the kit only verifies thermometers of the same type as its certified master: the serial numbers carry the letter A or O and both master and instrument under test must match, so the prefixes on the master and on all four thermometers are read before the set is relied on as a working whole. The certified master itself is a dated instrument, recertified by Exergen annually against the sticker on it, and the verifier carries a one year certification of its own, so a kit whose dates have passed will need recertifying before it can support a quality assurance record, which is a matter for the receiving organisation rather than something that can be judged from the outside. Scale matters too, since Exergen build the thermometers in Fahrenheit and preset Celsius versions and a United Kingdom ward needs Celsius, though the master itself switches between the two on a switch inside its battery compartment. In use the verifier warms for around five minutes, the instruments equilibrate in the same room for at least ten, every lens is cleaned with an alcohol swab, probe covers and sheaths are left off during verification, and a thermometer that reads outside tolerance is cleaned and re-read before it is judged, a dirty lens being the commonest reason for a low figure; recalibration itself is a factory operation rather than a field adjustment. The kit and its contents are wiped with alcohol or a mild cleaning solution and never immersed.
Specificațiile se pot modifica fără notificare prealabilă. Solicitați-ne dosarul tehnic actual.
Comenzile plasate până la ora 13:00, de luni până vineri, sunt expediate în aceeași zi lucrătoare din Leeds. Livrările se fac de luni până sâmbătă, niciodată duminica.
Regatul Unit continental, articole ușoare: între 1 și 2 zile lucrătoare. Articole grele și voluminoase: între 2 și 4 zile lucrătoare.
Comenzile internaționale sunt expediate în condiția livrat la locul de destinație (DAP). Taxele vamale de import, taxele locale și comisioanele de vămuire sunt percepute de țara de destinație și sunt în sarcina cumpărătorului.
Articolele nedesfăcute pot fi returnate în termen de 30 de zile de la livrare. Anunțați-ne înainte de a trimite ceva înapoi, pentru a vă putea oferi o referință de retur.
Din motive de igienă, articolele desfăcute care intră în contact cu căile respiratorii nu pot fi returnate, cu excepția cazului în care sunt defecte.
Citiți politica de returnare completă
Acest lucru nu vă afectează drepturile legale.
Rambursările se fac prin metoda de plată inițială după ce articolul returnat ajunge la noi și este verificat, de regulă în cinci zile lucrătoare.
Articolele defecte sunt rambursate integral, inclusiv costul de livrare pe care l-ați plătit.
Informațiile de pe această pagină au caracter orientativ și nu înlocuiesc sfatul unui profesionist calificat din domeniul sănătății. Citiți întotdeauna instrucțiunile producătorului înainte de utilizare și verificați dacă dispozitivul este potrivit pentru pacient și pentru terapia prescrisă.
Se adaugă la aceeași comandă.
Mai multe din aceeași categorie.
Continuați de unde ați rămas.
Written by people who bought from us.
Consultanță și îndrumare privind echipamentele medicale
October 04, 2026
The Alvera AirLink 360 Swivel is a 360-degree rotational CPAP connector that reduces tubing drag and helps maintain mask seal throughout ...
Citiți articolul
October 04, 2026
An honest pre-purchase guide to the Alvera AirLink Mini Mask Adapter Twin covering compatibility, included items, cleaning and clinical u...
Citiți articolul
October 04, 2026
Avoid the most common fitting, replacement and compatibility mistakes with the ALVERA PureGuard™ Universal In-Line Bacteria Filter. Pract...
Citiți articolulSelfiMed UK
BLACK FRIDAY
+ up to −80% on selected items, no code needed
Join our list for deal alerts, restocks and CPAP tips. Your code appears straight away.
Free UK mainland delivery over £300 · next-day dispatch before 1pm
By signing up you agree to receive marketing emails from SelfiMed UK. Unsubscribe at any time. Code valid on all products until Monday 30 November 23:59. One discount per item: items already at −50% or −80% keep that deal instead.
It's already in your basket, so 10% comes off at checkout.
Valid on all products. One discount per item. Ends Monday 30 November 23:59.