The Reliant 350 is Invacare's battery powered stand assist lift, carried in the United Kingdom as the RPS350-1E. It raises a patient from sitting to standing and moves them between seated surfaces, with a safe working load of 159 kg, or 25 stone, including the sling. It is supplied here with its battery and hand controller.
A stand assist is a different machine from a sling hoist and suits a different patient, which is worth being plain about before anything else. Invacare state that this lift is for transferring a person between seated surfaces, bed to wheelchair or chair to commode, and that it is not a transport device. It works by letting the patient take part in the transfer: they need enough trunk control to stay upright, enough strength to bear some weight through their legs, and the ability to hold the grips. A patient who cannot do those things needs a full sling hoist, not this.
Where a patient can do them, a stand aid is the better choice, and not only on cost. It takes less time than a full sling transfer, it keeps the patient upright and weight bearing rather than suspended, and it leaves the buttocks clear so that continence care and clothing can be dealt with during the transfer rather than as a separate handling job. For a care home doing the same transfer four or five times a day with one resident, that is a meaningful reduction in handling.
The mechanics are straightforward. The sling bar runs from 102 cm to 168 cm at the hook-up point. The base opens from 66 cm to 94 cm to clear a wheelchair or an armchair, with 11.5 cm of clearance underneath for castor bases. The whole lift stands 125 cm high, is 99 cm long and 65.5 cm wide, weighs 49 kg, and rolls on 8 cm front and 13 cm rear castors. The hand control raises, lowers and opens the legs; there is a red emergency stop on the control box and both electric and mechanical emergency lowering. Supplied pre-owned.
| Brand | Invacare |
| Range | Reliant |
| Model | Reliant 350 |
| United Kingdom and European model code | RPS350-1E, confirmed from the unit before dispatch |
| Device type | Stand assist patient lift, not a sling hoist |
| Safe working load | 159 kg, 25 stone, patient plus sling |
| Sling hook-up height | 102 cm to 168 cm |
| Sling type | Stand assist or transfer stand assist, not supplied |
| Statutory examination | LOLER 1998, at least every six months |
| Condition | Pre-owned |
Points to note before ordering
| Brand | Invacare |
| Model | Reliant 350 |
| United Kingdom and European model code | RPS350-1E |
| Condition | Pre-owned |
| Device type | Battery powered stand assist patient lift |
| Intended transfer | Between seated surfaces; not a transport device |
| Safe working load | 159 kg, 25 stone, patient plus sling |
| Sling hook-up height, minimum | 102 cm |
| Sling hook-up height, maximum | 168 cm |
| Base width, closed | 66 cm |
| Base width, open | 94 cm |
| Base length | 90 cm |
| Base clearance | 11.5 cm |
| Overall height | 125 cm |
| Overall length | 99 cm |
| Overall width | 65.5 cm |
| Unit weight | 49 kg |
| Castors, front | 8 cm |
| Castors, rear | 13 cm |
| Battery | 24 V direct current, 2.9 Ah |
| Charger input | 100 to 240 V alternating current, 50 or 60 Hz |
| Charger output | 29.5 V direct current |
| Charger type on the RPS350-1E | Wall mounted |
| Charge time | Up to 6 hours |
| Hand control | Raise, lower and open legs |
| Emergency stop | Red button on the control box, reset by rotation |
| Emergency lowering | Electric at the control box, with a mechanical release as backup |
| Slings | Stand assist or transfer stand assist, polyester, not supplied |
| Inspection interval | After the first 12 months, then every six months |
| Statutory examination | LOLER 1998, thorough examination at least every six months |
| Work equipment framework | Provision and Use of Work Equipment Regulations 1998 |
| Expected service life stated by the manufacturer | Eight years at around four lifts a day |
| Cleaning | Surface decontamination to local policy, no immersion of the control box or actuator |
| Commissioning | Electrical safety test and function check by Elarix Medical; LOLER thorough examination arranged separately |
| Item | Quantity |
| Invacare Reliant 350 stand assist patient lift, pre-owned | 1 |
| Battery | 1 |
| Hand controller | 1 |
| Charger | Confirmed before dispatch |
| Item | Status |
| Stand assist or transfer stand assist slings | Not included |
| Full body slings | Not compatible with this lift |
| Spare or second battery | Not included |
| Wall bracket for the charger | Confirmed before dispatch |
| Scales | Not included |
| LOLER thorough examination and certificate | Not included |
| Service history and maintenance records | Stated in writing before dispatch |
| Printed user manual | Not included |
| Decontamination certificate | Not included |
| Operator training | Not included |
Specificațiile se pot modifica fără notificare prealabilă. Solicitați-ne dosarul tehnic actual.
Comenzile plasate până la ora 13:00, de luni până vineri, sunt expediate în aceeași zi lucrătoare din Leeds. Livrările se fac de luni până sâmbătă, niciodată duminica.
Regatul Unit continental, articole ușoare: între 1 și 2 zile lucrătoare. Articole grele și voluminoase: între 2 și 4 zile lucrătoare.
Comenzile internaționale sunt expediate în condiția livrat la locul de destinație (DAP). Taxele vamale de import, taxele locale și comisioanele de vămuire sunt percepute de țara de destinație și sunt în sarcina cumpărătorului.
Articolele nedesfăcute pot fi returnate în termen de 30 de zile de la livrare. Anunțați-ne înainte de a trimite ceva înapoi, pentru a vă putea oferi o referință de retur.
Din motive de igienă, articolele desfăcute care intră în contact cu căile respiratorii nu pot fi returnate, cu excepția cazului în care sunt defecte.
Citiți politica de returnare completă
Acest lucru nu vă afectează drepturile legale.
Rambursările se fac prin metoda de plată inițială după ce articolul returnat ajunge la noi și este verificat, de regulă în cinci zile lucrătoare.
Articolele defecte sunt rambursate integral, inclusiv costul de livrare pe care l-ați plătit.
Informațiile de pe această pagină au caracter orientativ și nu înlocuiesc sfatul unui profesionist calificat din domeniul sănătății. Citiți întotdeauna instrucțiunile producătorului înainte de utilizare și verificați dacă dispozitivul este potrivit pentru pacient și pentru terapia prescrisă.
Se adaugă la aceeași comandă.
Mai multe din aceeași categorie.
Continuați de unde ați rămas.
Written by people who bought from us.
Consultanță și îndrumare privind echipamentele medicale
October 04, 2026
The Alvera AirLink 360 Swivel is a 360-degree rotational CPAP connector that reduces tubing drag and helps maintain mask seal throughout ...
Citiți articolul
October 04, 2026
An honest pre-purchase guide to the Alvera AirLink Mini Mask Adapter Twin covering compatibility, included items, cleaning and clinical u...
Citiți articolul
October 04, 2026
Avoid the most common fitting, replacement and compatibility mistakes with the ALVERA PureGuard™ Universal In-Line Bacteria Filter. Pract...
Citiți articolul