The ResMed Lumis 150 VPAP is a bilevel positive airway pressure device designed for non-invasive ventilatory support. It delivers a higher pressure on inhalation and a lower pressure on exhalation, making it suitable for patients whose breathing patterns require more active pressure support than a standard CPAP can provide. Before ordering, most buyers have the same set of questions. This article addresses them directly.

What the ResMed Lumis 150 VPAP Actually Does

Bilevel therapy versus standard CPAP

A CPAP device delivers one fixed pressure throughout the night. The Lumis 150 VPAP delivers two pressures: an inspiratory positive airway pressure (IPAP) and a lower expiratory positive airway pressure (EPAP). This distinction matters clinically. Patients who find a single pressure difficult to exhale against, or who need ventilatory support beyond simple airway splinting, are typically prescribed a bilevel device rather than a standard CPAP.

The Lumis 150 sits at the higher end of ResMed's Lumis range and supports spontaneous (S), spontaneous-timed (ST) and timed (T) modes, allowing it to be configured in response to a wide range of prescribed protocols.

Integrated humidification

The device is compatible with ResMed's HumidAir humidifier, which attaches directly to the unit. Humidification reduces the risk of rainout and improves comfort throughout the night, particularly for patients using higher pressure settings or those with sensitivity to dry air. The HumidAir chamber and heated tubing (ClimateLineAir) are consumables sold separately. Check whether these are included before ordering any pre-owned unit.

Connectivity and compliance monitoring

The Lumis 150 VPAP includes wireless connectivity for remote monitoring. Therapy data, including compliance hours, leak rate and breathing pattern information, is transmitted via the AirView platform. This matters for clinical follow-up: prescribers and sleep services rely on this data to assess whether therapy settings remain appropriate. Confirm that the device's wireless functionality is active and has been reset to factory defaults if purchasing a pre-owned unit.

ResMed Lumis 150 VPAP ST-A BIPAP Unit - Complete Bundle - Refurbished complete bundle refurbished SelfiMed UK

ResMed Lumis 150 VPAP ST-A BIPAP Unit - Complete Bundle - Refurbished

£869.99

Buy nowView product

What Is and Is Not Included

Standard device contents

A new Lumis 150 VPAP shipped by ResMed typically includes the main unit, a power supply, an air filter and basic documentation. It does not include a humidifier, water chamber, heated tubing, mask, cushion, headgear or carry bag as standard. Each of these is available separately and must be ordered to complete a working therapy setup.

  • Main unit, the Lumis 150 VPAP device itself, with power supply
  • Air filter, a consumable requiring periodic replacement, interval per manufacturer guidance
  • Documentation, quick-start guide and compliance information
  • HumidAir humidifier, not included as standard, sold separately
  • ClimateLineAir heated tubing, not included, sold separately and compatible with HumidAir
  • Mask and interface, not included, prescribed and sourced separately
  • Water chamber, a single-use consumable, not included, replaced on a schedule set by the manufacturer

Pre-owned units: ask before ordering

Pre-owned Lumis 150 VPAP devices may be offered with some accessories present and others absent. The condition of the humidifier, water chamber and tubing on any pre-owned unit should be confirmed before ordering. Water chambers are single-use consumables and should not be reused between patients. Photographs form part of the description for any pre-owned listing: review them carefully and ask before ordering if any item's status is unclear.

Compatibility with masks and tubing

The Lumis 150 VPAP uses a standard 22 mm connection. Most ResMed full face, nasal and nasal pillow masks are compatible, but the prescribed interface should always be confirmed with the treating clinician. Heated tubing requires ClimateLineAir specifically: standard smooth-bore tubing can be used but without the temperature control benefits. Check compatibility restrictions before ordering any interface or tubing separately.

Condition, History and Inspection

New versus pre-owned: what the distinction means

A new Lumis 150 VPAP is supplied in original ResMed packaging, contents checked against the packing list. Commissioning, verification and initial therapy setup remain with the operating organisation or prescribing clinician. A pre-owned unit will have usage hours recorded in its internal data log. Ask for hours-of-use information before purchasing. A cleaned and inspected pre-owned unit has been checked for function in-house, but this is not a full engineer service or calibration unless explicitly stated.

What in-house checks cover

In-house workshop checks on a pre-owned Lumis 150 VPAP typically include a visual inspection for physical damage, a power-on function test, a check that the device reaches prescribed pressures and a review of alarm function. These are in-house checks only. Damaged or non-working units are not dispatched. A full engineer service, pressure calibration verification and planned maintenance remain with the operating organisation, following the manufacturer's service schedule.

Data reset and patient privacy

A pre-owned device should have its patient data cleared and wireless credentials reset before transfer. Confirm this has been done. If a device retains data from a previous patient, it must be cleared before use in line with data protection obligations and clinical governance requirements. Ask before ordering if the reset status is not explicitly stated in the listing.

Practical Setup and Ongoing Maintenance

Consumables that need routine replacement

Several components of a Lumis 150 VPAP setup require periodic replacement regardless of whether the device itself is new or pre-owned. The manufacturer's instructions take precedence over any general guidance given here.

  • Air filter, inspect weekly, replace at least every six months or when visibly contaminated
  • Water chamber, a single-use consumable, replace at the interval specified by ResMed, never reuse between patients
  • Mask cushion, replace regularly to maintain seal integrity, frequency depends on usage and material
  • Headgear, replace when elasticity is lost and seal is compromised
  • Heated tubing, inspect for cracks or kinks, replace per manufacturer guidance

Humidifier and rainout management

Rainout (condensation inside the tubing) is a common complaint when using humidification without heated tubing. The ClimateLineAir heated tube is designed to maintain air temperature throughout its length, reducing rainout throughout the night. If heated tubing is not available, reducing the humidifier output or increasing the room temperature may help, but the ClimateLineAir tube is the recommended solution. Refer to the manufacturer instructions for humidifier settings.

Cleaning protocol

The external casing should be wiped down with a damp cloth. The mask, cushion and headgear should be cleaned daily with mild soap and water. The water chamber should be rinsed daily and allowed to air dry. Do not use bleach, alcohol or abrasive cleaners on any component unless the manufacturer explicitly permits it. Follow the ResMed cleaning protocol as the primary reference.

Summary: Key Points Before You Order

The ResMed Lumis 150 VPAP is a bilevel ventilatory support device, not a standard CPAP. It is prescribed, and therapy settings must be configured by a qualified clinician before use. The device does not include a humidifier, mask or heated tubing as standard: these are sold separately and must be sourced and confirmed before setup. Pre-owned units should be checked for usage hours, data reset status and the presence or absence of accessories. Consumables including the water chamber and air filter require routine replacement on the manufacturer's stated schedule. If any specification, compatibility or condition detail is unclear, ask before ordering.

ResMed Lumis 150 VPAP ST-A BIPAP Unit - Complete Bundle - Refurbished complete bundle refurbished SelfiMed UK

Ready to move forward with the ResMed Lumis 150 VPAP ST-A BIPAP Unit - Complete Bundle - Refurbished?