An Exergen calibration verification kit, part 129062, supplied with four TemporalScanner infrared temporal artery thermometers: two of the current TAT-5000S and two of the preceding TAT-5000. The kit holds a certified master reference thermometer, a portable handheld blackbody target and a mains supply with international adapter blades, in a rugged case, and it verifies thermometers against the master on the bench rather than sending them away.
This is what turns a set of thermometers into a managed estate. A clinical thermometer is a measuring instrument, and an instrument whose accuracy nobody has checked is an instrument nobody should be charting from. Exergen's answer is a portable blackbody held at body temperature, between 36 and 40 degrees Celsius, and a certified master thermometer kept alongside it. Both the master and the instrument under test read the same target in turn, and the two figures are compared. A TAT-5000 or TAT-5000S passes if it agrees with the master within 0.2 degrees Celsius.
The procedure is deliberately undramatic, which is why a ward can run it. The verifier warms up for about five minutes, the thermometers sit in the same room for at least ten so everything is at one temperature, every lens including the master's is wiped with an alcohol swab, and readings are then taken alternately. On a large batch the master is re-read about every ten instruments so its own drift does not go unnoticed. Exergen note that a dirty lens is the commonest cause of a low reading, so a cleaning and a repeat comes before any conclusion that an instrument has failed.
The kit covers the whole TemporalScanner family rather than one generation, which is why a mixed set like this one works with it: Exergen list the TAT-2000, TAT-2000C, TAT-5000 and TAT-5000S as applicable models. The two TAT-5000S units are the current generation, released as the successor to the TAT-5000 with the same stated accuracy and a revised housing, and all four read to 0.1 degrees Celsius with a clinical accuracy of plus or minus 0.1 degrees Celsius to ASTM E1112.
| Brand | Exergen |
| Kit | Calibration verification kit, part 129062 |
| Thermometers supplied | Two TemporalScanner TAT-5000S and two TemporalScanner TAT-5000 |
| Verification principle | Comparison against a certified master reading a blackbody target |
| Blackbody target range | 36 to 40 degrees Celsius |
| Pass tolerance for the 5000 series | Within 0.2 degrees Celsius of the certified master |
| Applicable models | TAT-2000, TAT-2000C, TAT-5000 and TAT-5000S |
| Thermometer accuracy | Plus or minus 0.1 degrees Celsius, to ASTM E1112 |
| Condition | Pre-owned |
Points to note before ordering
Exergen calibrate these instruments two ways, arterial and oral equivalent, and the kit only verifies thermometers of the same type as its certified master: the serial numbers carry the letter A or O and both master and instrument under test must match, so the prefixes on the master and on all four thermometers are read before the set is relied on as a working whole. The certified master itself is a dated instrument, recertified by Exergen annually against the sticker on it, and the verifier carries a one year certification of its own, so a kit whose dates have passed will need recertifying before it can support a quality assurance record, which is a matter for the receiving organisation rather than something that can be judged from the outside. Scale matters too, since Exergen build the thermometers in Fahrenheit and preset Celsius versions and a United Kingdom ward needs Celsius, though the master itself switches between the two on a switch inside its battery compartment. In use the verifier warms for around five minutes, the instruments equilibrate in the same room for at least ten, every lens is cleaned with an alcohol swab, probe covers and sheaths are left off during verification, and a thermometer that reads outside tolerance is cleaned and re-read before it is judged, a dirty lens being the commonest reason for a low figure; recalibration itself is a factory operation rather than a field adjustment. The kit and its contents are wiped with alcohol or a mild cleaning solution and never immersed.
Les caractéristiques peuvent changer sans préavis. Demandez-nous le dossier technique à jour.
Les commandes passées avant 13h00, du lundi au vendredi, sont expédiées le jour ouvré même depuis Leeds. Les livraisons ont lieu du lundi au samedi, jamais le dimanche.
Royaume-Uni (hors îles), articles légers : 1 à 2 jours ouvrés. Articles lourds et volumineux : 2 à 4 jours ouvrés.
Les commandes internationales sont expédiées en rendu au lieu de destination (DAP). Les droits d'importation, les taxes locales et les frais de dédouanement sont facturés par le pays de destination et restent à la charge de l'acheteur.
Les articles non ouverts peuvent être retournés dans les 30 jours suivant la livraison. Prévenez-nous avant tout renvoi afin que nous puissions vous communiquer une référence de retour.
Pour des raisons d'hygiène, les articles ouverts en contact avec les voies respiratoires ne peuvent pas être retournés, sauf s'ils sont défectueux.
Lire la politique de retour complète
Cela n’affecte pas vos droits légaux.
Les remboursements sont effectués sur le moyen de paiement d'origine une fois l'article retourné reçu et vérifié, normalement sous cinq jours ouvrés.
Les articles défectueux sont remboursés intégralement, y compris les frais de livraison que vous avez payés.
Les informations de cette page sont fournies à titre indicatif et ne remplacent pas l'avis d'un professionnel de santé qualifié. Lisez toujours les instructions du fabricant avant utilisation et vérifiez que l'appareil convient au patient et au traitement prescrit.
Ajouté à la même commande.
Plus de produits dans la même catégorie.
Reprenez là où vous vous étiez arrêté.
Written by people who bought from us.
Conseils et accompagnement sur le matériel médical
October 04, 2026
The Alvera AirLink 360 Swivel is a 360-degree rotational CPAP connector that reduces tubing drag and helps maintain mask seal throughout ...
Lire l’article
October 04, 2026
An honest pre-purchase guide to the Alvera AirLink Mini Mask Adapter Twin covering compatibility, included items, cleaning and clinical u...
Lire l’article
October 04, 2026
Avoid the most common fitting, replacement and compatibility mistakes with the ALVERA PureGuard™ Universal In-Line Bacteria Filter. Pract...
Lire l’articleSelfiMed UK
BLACK FRIDAY
+ up to −80% on selected items, no code needed
Join our list for deal alerts, restocks and CPAP tips. Your code appears straight away.
Free UK mainland delivery over £300 · next-day dispatch before 1pm
By signing up you agree to receive marketing emails from SelfiMed UK. Unsubscribe at any time. Code valid on all products until Monday 30 November 23:59. One discount per item: items already at −50% or −80% keep that deal instead.
It's already in your basket, so 10% comes off at checkout.
Valid on all products. One discount per item. Ends Monday 30 November 23:59.