Chat disponible 24h/24 et 7j/7
Chat disponible 24h/24 et 7j/7
Brand new
Price shown excludes VAT.
VAT relief available on this product
Eligible customers can claim VAT relief on this product at checkout.
Add the whole set in one go.
Alvera ThermaAir™ 10 Heated CPAP Tubing
£29.99
This item
Alvera ThermaAir 10 is a compatible heated tube for Air 10 series therapy machines. It works with the machine's own climate control settings and heated humidifier, so the temperature is set on the machine rather than through a separate controller.
A heated tube solves one specific problem. Standard tubing loses heat across the length of the hose, the warm humidified air cools, and the moisture it was carrying condenses on the inside wall. That condensation is rainout, and it arrives as a spatter of cold water in the mask at three in the morning.
Air holds moisture in proportion to its temperature. Warm air leaving a humidifier at around 30 degrees C carries a given amount of water vapour. Push that same air down an unheated hose lying across a cold bedroom floor and it drops several degrees before it reaches the mask, at which point it can no longer hold what it was carrying and the surplus condenses. The result is a wet hose, a gurgling noise, water in the cushion, and a wearer who turns the humidifier down or off. Turning it down stops the rainout and brings back the dry mouth, blocked nose and sore throat the humidifier was fitted to prevent.
A heating element running the length of the hose breaks that cycle. It holds the air above its dew point all the way to the mask, so the humidity setting can be raised to what the airway needs rather than reduced to what the tubing will tolerate. The difference shows most in cold bedrooms, at higher humidity settings, with full face masks and higher pressures, and for anyone whose mask leaks or who breathes through their mouth. Comfort is what keeps therapy in use, and nasal dryness and a wet hose are two of the most cited reasons people abandon it.
| Reference | Product | GTIN | Fits |
|---|---|---|---|
| 55110 | Alvera ThermaAir 10 heated tube | 5065027735385 | Air 10 series machines with heated humidifier and climate control |
Check the machine before ordering. ThermaAir 10 is made for Air 10 series machines, including AirSense 10, AirCurve 10 and Lumis series devices. It does not fit AirSense 11 or AirMini machines, which use different connections. A heated tube also requires a machine fitted with a heated humidifier and a climate control function, and the machine must recognise the tube before the heating element will operate. Where the machine model is not certain, ask before ordering.
Safe use. This is a mains powered accessory carrying an electrical heating element. Do not immerse the connector end in water, and do not put the tube in a dishwasher or a washing machine. Do not use a tube with a damaged connector, a split, a kink, a crushed section, or any sign of moisture inside the connector: take it out of service and fit a fresh one. Allow the tube to dry fully before use after cleaning. Do not run the tube under bedding, a mattress or anything else that traps heat, and do not use it with an added heat source. Do not modify the tube, cut it, or extend it with additional lengths of hose. Humidification settings should follow the guidance of the service responsible for the wearer's care.
Cleaning and renewal. Wash weekly in warm water with a mild detergent, keeping the connector end clear of the water. Rinse thoroughly and hang to dry away from direct sunlight, which degrades the material. Inspect weekly for splits, kinks, crushed sections, a loose cuff and moisture inside the connector. Route the tube each night so it is not trapped or pinched. Fit a fresh tube at the interval set by the service responsible for care, typically every three to six months, or sooner if damage or persistent cloudiness appears. The instructions supplied with the machine and with the tube take precedence over this general guidance.
Specifications can change without notice. Ask us for the current technical file.
Further documentation is available on request.
Ordered before 1pm Monday to Friday, dispatched the same working day from Leeds. Deliveries run Monday to Saturday, never Sunday.
UK mainland, light items: 1 to 2 working days. Heavy and bulky: 2 to 4 working days.
International orders ship on a Delivered At Place basis. Import duty, local tax and customs clearance fees are charged by the destination country and are the buyer's responsibility.
Unopened items can be returned within 30 days of delivery. Tell us before you send anything back so we can give you a returns reference.
Opened items that touch the airway cannot be returned for hygiene reasons unless they are faulty.
This does not affect your statutory rights.
Refunds are issued to the original payment method once the returned item reaches us and has been checked, normally within five working days.
Faulty items are refunded in full, including the delivery you paid.
Information on this page is provided for guidance and does not replace advice from a qualified clinician. Always read the manufacturer's instructions before use, and check that a device is suitable for the patient and the prescribed therapy.
Goes on the same order.
More in the same category.
Picking up where you left off.
Conseils et orientation concernant l'équipement médical
August 26, 2026
Avoid the most common fitting, cleaning and ordering mistakes with the ResMed QuietAir Elbow. Practical, factual guidance for clinicians ...
Lire l'article
August 26, 2026
A plain factual guide to the Sidhil Innov8 iQ Electric profiling bed: what it does, what to check before ordering and what maintenance in...
Lire l'article
August 26, 2026
Avoid the most common installation, maintenance and ordering mistakes with the ALVERA PureGuard™ Universal In-Line filter, with plain fac...
Lire l'article