Chat disponibile 24/7
Chat disponibile 24/7
The Arjo Tenor Bariatric Mobile Patient Hoist is a floor-based, mobile lifting device designed for the transfer and repositioning of bariatric patients in clinical and care environments. It is built to accommodate higher safe working loads than standard hoists, and it is commonly used across wards, rehabilitation departments and residential care settings where patient weight or size exceeds the capacity of conventional equipment.
The Tenor Bariatric is a powered mobile hoist. An electric actuator raises and lowers the boom, reducing manual handling effort for the operator. The mast and boom geometry is designed to allow sling attachment at a height and angle suited to bariatric transfers, including bed-to-chair, chair-to-toilet and floor lifts when a compatible sling is used.
The safe working load (SWL) is a critical specification. The Tenor Bariatric is rated for loads above the standard Tenor. Confirm the exact SWL for the specific unit before ordering, as different production variants exist. The lowest SWL in the complete system governs: if the sling is rated lower than the hoist, the sling rating applies. Never exceed the lowest rated component in the system.
The powered or manually adjustable leg spread allows the chassis to pass around furniture legs and position under beds or chairs. A wide leg stance increases stability during the lift. Check whether the leg spread mechanism on the specific unit is manual or electrically powered, as this affects operational requirements in confined spaces.
![]() |
Arjo Tenor Bariatric Mobile Patient Hoist with Weighing Scale £449.99 Buy nowView product |
The Tenor Bariatric uses a spreader bar compatible with Arjo sling ranges. Slings are consumables and are sold separately. Sling selection must account for the patient's weight, body shape, clinical condition and the type of transfer being performed. A competent person must select the appropriate sling. The hoist and sling must both be rated at or above the patient's weight, and the lower of the two ratings governs.
Six castors, typically with directional locking on the rear pair, allow the hoist to be steered and parked securely. Castor condition on pre-owned units should be inspected. Worn or seized castors affect control during a transfer and must be replaced before clinical use.
The Lifting Operations and Lifting Equipment Regulations 1998 (LOLER) apply to patient hoists used in a workplace. A thorough examination by a competent person is required at least every six months. This examination is separate from any in-house functional check. The operating organisation is responsible for arranging and recording this examination. A hoist that has not been examined within the required period must not be used for lifting operations.
The Provision and Use of Work Equipment Regulations 1998 (PUWER) require the equipment to be maintained in a safe condition, inspected at appropriate intervals, and used only by trained operators. Planned maintenance, electrical safety testing and operator training remain with the operating organisation.
Any pre-owned hoist must be decontaminated before clinical use. The operating organisation must follow its own decontamination protocol. The manufacturer's instructions take precedence over any general guidance provided here. Confirm that the surface materials of the specific unit are compatible with the cleaning agents used in the receiving department before ordering.
Slings are not included with a hoist unless the listing states otherwise. They are single-patient or limited-use consumables and must be selected individually. Ask before ordering if you need guidance on compatible Arjo sling references for the Tenor Bariatric spreader bar.
The battery charger may or may not be included with a pre-owned unit. If the charger is absent, it is an essential add-on: the hoist cannot be used without a functioning battery and a means of charging it. Confirm charger inclusion before completing an order. Spare batteries are sold separately.
Previous LOLER examination certificates and service records may not accompany a pre-owned unit. The absence of documentation does not indicate a fault, but it does mean the receiving organisation must arrange a thorough examination before placing the hoist in clinical use.
The Tenor range includes standard and bariatric variants, and within the bariatric range there are differences in SWL, leg drive and scale options. Photographs form part of the description on any used listing. Review them carefully and ask for additional images or the model plate reference if the variant is not clear.
A pre-owned Tenor Bariatric that has been cleaned, inspected and function tested offers a cost-effective route to bariatric lifting capacity. The receiving organisation must still arrange a LOLER thorough examination before clinical use. A new unit carries full manufacturer warranty and no requirement to establish prior history, but lead times and cost are typically higher.
The Arjo Tenor Bariatric Mobile Patient Hoist is a capable, well-established bariatric transfer device suited to clinical and care environments. Before ordering, confirm the safe working load of the specific unit, whether the charger is included, whether integrated scales are fitted, and the current battery condition. Slings are sold separately and must be selected by a competent person. LOLER thorough examination is required before clinical use regardless of the condition of the unit at dispatch. Any questions about model variant, included accessories or decontamination compatibility should be resolved before ordering.
![]() |
Ready to move forward with the Arjo Tenor Bariatric Mobile Patient Hoist with Weighing Scale? Shop the Arjo Tenor Bariatric Mobile Patient Hoist with Weighing Scale |