ResMed SlimLine 15 mm CPAP Tubing, 6 ft, Unheated

SlimLine is ResMed's narrow bore air tubing: 15 mm internal diameter against the 19 mm of a standard hose, roughly 40 per cent lighter and taking up about 35 per cent less space. Less weight hanging off the mask means less tube drag, which is the pull that breaks a seal when the wearer turns over.

Six feet long with 22 mm smart-fit cuffs at each end. This is unheated tubing and does not support Climate Control, which needs a ClimateLineAir heated tube instead.

What is included

Item Detail Condition
SlimLine air tubing One 6 ft hose, 15 mm internal diameter, with smart-fit cuffs NEW

What is not included

Item Detail Status
Mask and headgear Connects to the 22 mm cuff at the mask end SOLD SEPARATELY
Heated tubing ClimateLineAir, where Climate Control is wanted SOLD SEPARATELY
Tubing wrap or cover Insulating sleeve for a cold bedroom SOLD SEPARATELY
Device or humidifier This listing is tubing only NOT INCLUDED

Set the tube type on the device after fitting

  • Devices that offer a tube setting must be set to SlimLine, or to a 15 mm hose diameter, once this tubing is fitted. The device compensates for the resistance of the tube it believes is attached, so leaving it set to a standard 19 mm hose changes the pressure actually delivered at the mask.
  • The setting is changed by the wearer or the clinical service in the device menu, following the device user guide.
  • Fit fresh tubing before first use on a new wearer. Tubing is not carried over between people.

What narrow bore tubing actually changes

The complaint that ends most CPAP therapy is not pressure. It is the mask breaking seal in the night, and the most common cause is tube drag: the weight of a metre and a half of hose pulling sideways on the mask every time the wearer turns over. A standard 19 mm hose is heavier and stiffer, and it transfers that weight straight to the cushion. Dropping to 15 mm removes roughly 40 per cent of the mass and a good deal of the stiffness, so the same movement pulls the mask far less. For side sleepers this is often the single change that makes a mask work.

Narrower bore also means higher flow resistance, which is why the device has a tube setting at all. ResMed devices apply a compensation curve for the hose they are told is attached, so the prescribed pressure arrives at the mask rather than at the machine outlet. Fitting SlimLine and leaving the device on the standard setting is the one mistake that matters here, and it is easily made because everything still appears to work.

Two limits are worth stating. This is an unheated tube, so in a cold bedroom with humidification set high, condensation can form along its length. Rainout is the reason ClimateLineAir exists, and a tubing wrap is the cheaper partial answer. And SlimLine is designed for ResMed devices that accept a 15 mm hose, which covers the S9, AirStart 10, AirSense 10 and 11, and AirCurve 10 and 11. It is not the right tube for the AirMini, and machines built around a 22 mm bore need their own hose.

Key features

15 mm internal bore against the standard 19 mm, which is where the weight saving comes from and therefore where the reduction in tube drag comes from.
Roughly 40 per cent lighter and 20 per cent thinner than a standard hose, so the mask is pulled less when the wearer changes position during the night.
About 35 per cent less bulk, which is a practical difference when the tube is coiled into a travel bag alongside the device and humidifier.
Smart-fit cuffs at both ends, pushing on and pulling off without force, which matters on a part handled twice a day and cleaned weekly.
22 mm connections, the standard mask and device fitting, so the narrow bore is internal and does not restrict which mask can be used.
More flexible along its length, so the tube follows the wearer rather than holding a coil and springing back against the mask.
Contains no latex, keeping it usable by anyone with a latex sensitivity.

Technical specifications

Manufacturer ResMed
Product SlimLine air tubing
Condition New
Internal diameter 15 mm
Connections 22 mm smart-fit cuffs, both ends
Length 6 ft, approximately 1.8 m
Heating Unheated. Does not support Climate Control
Latex Contains no latex
Device setting required Tube type set to SlimLine, or hose diameter set to 15 mm
Compatible devices ResMed S9 series, AirStart 10, AirSense 10 and 11, AirCurve 10 and 11
Not compatible with AirMini, and devices requiring a 22 mm bore or a heated tube

Specification limited to what is confirmed

  • The ResMed part number is confirmed against the pack before dispatch rather than published from a distributor catalogue.
  • Exact length, packed weight and material composition follow the manufacturer's own literature and are given on request.
  • Compatibility with a device outside the list above is checked against the ResMed data management and device compatibility documentation before ordering.

SlimLine compared with the alternatives

Tubing When it is the right choice
SlimLine, 15 mm unheated Reducing tube drag and bulk, on a device that accepts a 15 mm hose
Standard, 19 mm unheated Devices that require a 22 mm bore, or where a universal hose is wanted
ClimateLineAir heated Cold bedrooms and rainout, where Climate Control holds temperature and humidity at the mask
Tubing wrap over SlimLine A partial answer to condensation without moving to heated tubing

Routine care schedule

Task Interval
Wash in warm water with a mild detergent, rinse and hang to dry away from direct sunlight Weekly
Inspect the length and both cuffs for splits, holes or hardening Weekly
Renew the tubing Every 1 to 3 months, or sooner if damaged

Intervals follow manufacturer guidance and are shortened where the device is used in a shared or institutional setting.